Adjusted Temperature 37degree High Flow Nasal Cannula Device 60A

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-60A
Minimum Order Quantity: 2 units
Price: negotiable
Packaging Details: main unit 50*41*33CM, trolley 85*63*24CM
Delivery Time: 5~8 work days
Payment Terms: L/C, T/T
Supply Ability: 1500 units/week
Detail Information
Oxygen Ajustment: Manual Oxygen Range: 21%~100%
Flow: 10-60L/min Temperature: 31℃,34℃ 37℃
Trend Review: 1,3,7 Days
High Light:

Adjusted Temperature High Flow Nasal Cannula Device

,

Temperature 37degree High Flow Nasal Cannula Device

,

Adjusted Temperature high flow oxygen delivery devices


Product Description

Micomme user-friendly high flow nasal cannula oxygen therapy device 60A 

 

 

Description

A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.

 

HFNC is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. It is considered to have a number of physiological effects: it improves oxygenation, dynamic lung compliance, homogeneity and end expiratory lung volume; it decreases anatomical dead space and generates a positive airway pressure that can reduce respiratory rate, the work of breathing, and enhance patient comfort.

 

 

Application

HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.

 

The use of HFNC in patients with Hypercapnic Respiratory Failure, COPD.

 

 

Advantage

The first company to research, develop and produce high-flow in China.

 

At present, micomme occupies over 50% market share in high flow filed in China.

 

Intelligent temperature and humidity control system

  • Providing air with core body temperature and 100% relative humidity
  • Adjustable temperature from 31℃ to 37℃

 

Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.

 

The machine uses timing function, which is convenient for nurses to charge by time.

 

Adjusted Temperature 37degree High Flow Nasal Cannula Device 60A 0

 

 

Specifications

Parameters OH-60A
Oxygen Adjustment Setting Manual
Oxygen Adjustment Range 21%- 100%
Low flow mode 2- 25L/min
High flow mode 10- 60L/min
Temperature settings 31℃,34℃,37℃
Real time display parameters Preset Flow, Preset FiO2, Preset Temperature, Treatment time
Trend review 1,3,7 days review
Content of review Flow, FiO2, Temperature, Treatment time
Presetting of treatment time Yes
Auto reminder of maintenance Yes
Main device disinfection No need disinfection for circuits system
Wipe disinfection for device surface
Screen

4.3 inches

Dimension 340*228*162mm
Weight 3.3kg
Alarm Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm,
temperature alarm, power down alarm, low ambient temperature alarm,
FiO2 not reaching preset value alarm, flow not reaching preset value
alarm, reaching preset treatment time alarm

 

 