Oxygen Ajustment: | Manual | Oxygen Range: | 21%~100% |
---|---|---|---|
Flow: | 10-60L/min | Temperature: | 31℃,34℃ 37℃ |
Trend Review: | 1,3,7 Days | ||
High Light: | Adjusted Temperature High Flow Nasal Cannula Device,Temperature 37degree High Flow Nasal Cannula Device,Adjusted Temperature high flow oxygen delivery devices |
Micomme user-friendly high flow nasal cannula oxygen therapy device 60A
Description
A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.
HFNC is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. It is considered to have a number of physiological effects: it improves oxygenation, dynamic lung compliance, homogeneity and end expiratory lung volume; it decreases anatomical dead space and generates a positive airway pressure that can reduce respiratory rate, the work of breathing, and enhance patient comfort.
Application
HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.
The use of HFNC in patients with Hypercapnic Respiratory Failure, COPD.
Advantage
The first company to research, develop and produce high-flow in China.
At present, micomme occupies over 50% market share in high flow filed in China.
Intelligent temperature and humidity control system
Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
The machine uses timing function, which is convenient for nurses to charge by time.
Specifications
Parameters | OH-60A |
Oxygen Adjustment Setting | Manual |
Oxygen Adjustment Range | 21%- 100% |
Low flow mode | 2- 25L/min |
High flow mode | 10- 60L/min |
Temperature settings | 31℃,34℃,37℃ |
Real time display parameters | Preset Flow, Preset FiO2, Preset Temperature, Treatment time |
Trend review | 1,3,7 days review |
Content of review | Flow, FiO2, Temperature, Treatment time |
Presetting of treatment time | Yes |
Auto reminder of maintenance | Yes |
Main device disinfection | No need disinfection for circuits system Wipe disinfection for device surface |
Screen |
4.3 inches |
Dimension | 340*228*162mm |
Weight | 3.3kg |
Alarm | Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching preset treatment time alarm |