OH-70C Medical Automatic 10-70L/Min High Flow Nasal Cannula Device

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-70C
Minimum Order Quantity: 10 units
Price: Negotiable
Packaging Details: 78*49*32CM/main unit ; 70*55*23.5CM/trolley
Delivery Time: 10 working days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Oxygen Adjustment: Automatic Oxygen Range: 21%- 100%
Low Flow Mode: 2- 25L/min High Flow Mode: 10- 70L/min
Temperature Settings: 31℃-37℃ Screen: 4.3 Inches
Trend Review: 1、3、7 Days Review Dimension: 340*228*162mm
High Light:

OH-70C High Flow Nasal Cannula Device

,

70L/Min High Flow Nasal Cannula Device

,

70L/Min high flow nasal cannula machine


Product Description

Medical automatic 10-70L/Min high flow nasal cannula device 70C
 
Description
 High Flow Nasal Cannula (HFNC) isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’s flow and fi02 requirements.
 
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.
 
Application
 When HFNC is applied, the constant high flow of oxygen provides a washout of the anatomical dead space of the oropharynx and proximal tracheobronchial tree, which results in more efficient breathing. 
In physiological terms, HFNC improves the fraction of inspired oxygen, washes and reduces dead space, generates positive end-expiratory pressure (PEEP) and provides more comfort than cold and dry oxygen.
 
OH-70C Medical Automatic 10-70L/Min High Flow Nasal Cannula Device 0
 
Advantage
 In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
 
In 2020, micomme ranked the sixth in export of medical respiratory devices in China.
 
Effectively reduce the dead space with 70L/min high flow
 
The machine uses timing function, which is convenient for nurses to charge by time.
 
Disposable heated tube and water chamber.
 
OH-70C Medical Automatic 10-70L/Min High Flow Nasal Cannula Device 1  OH-70C Medical Automatic 10-70L/Min High Flow Nasal Cannula Device 2
 
Specifications

ModelOH-70C
Oxygen AdjustmentSettingAutomatic
Range21%-100%

 
Flow

Low flow mode2-25L/min
High flow mode10-70L/min
Temperature settings31℃-37℃
Real time monitoring parametersFlow, FiO2, Temperature, Treatment time

 
 
 
Data

Trend review1,3,7 days review
Content of reviewFlow, FiO2, Temperature, Treatment time
Presetting of treatment timeYes

 
 
Management

Auto reminder of maintenanceYes
Main device disinfection

No need disinfection for circuits system
Wipe disinfection for device surface

Screen4.3 inches
Dimension340*228*162mm
Weight3.3kg

 
 
 
Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm

 