products

CE Certified 34degree Temperature High Flow Nasal Cannula Device 60A

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-60A
Minimum Order Quantity: 10 units
Price: Negotiable
Packaging Details: 78*49*32CM/main unit ; 70*55*23.5CM/trolley
Delivery Time: 10 working days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Oxygen Adjustment: Manual Oxygen Range: 21%- 100%
Low Flow Mode: 2- 25L/min High Flow Mode: 10- 60L/min
Temperature Settings: 31℃, 34℃,37℃ Screen: 4.3 Inches
Trend Review: 1、3、7 Days Review Dimension: 340*228*162mm
High Light:

34degree Temperature High Flow Nasal Cannula Device

,

CE Certified High Flow Nasal Cannula Device

,

34degree Temperature high flow nasal cannula machine


Product Description

CE Certified 34degree Temperature High Flow Nasal Cannula Device 60A
 
Description
High Flow Nasal Cannula (HFNC) is a heated and humidified system that allows prescribed fraction of inspired oxygen (FIO2) levels to be delivered at very high flow rates.
 
High Flow Nasal Cannula (HFNC) isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’s flow and fi02 requirements.
 
 
Application
Its use has been widely explored, particularly in ICUs and emergency departments (EDs)
 
When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!
 
Advantage
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
 
During the pandemic, micomme provided over 7000 units of devices globally.
 
 Intelligent temperature and humidity control system

  • Providing air with core body temperature and 100% relative humidity
  • Adjustable temperature from 31℃ to 37℃

 
Effectively reduce the dead space with 60L/min high flow
 
 Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
 
CE Certified 34degree Temperature High Flow Nasal Cannula Device 60A 0  CE Certified 34degree Temperature High Flow Nasal Cannula Device 60A 1
 
Specifications

ModelOH-60A
Oxygen AdjustmentSettingManual
Range21%-100%

 
Flow

Low flow mode2-25L/min
High flow mode10-60L/min
Temperature settings31℃, 34℃,37
Real time monitoring parametersFlow, FiO2, Temperature, Treatment time

 
 
 
Data

Trend review1,3,7 days review
Content of reviewFlow, FiO2, Temperature, Treatment time
Presetting of treatment timeYes

 
 
Management

Auto reminder of maintenanceYes
Main device disinfection

No need disinfection for circuits system
Wipe disinfection for device surface

Screen4.3 inches
Dimension340*228*162mm
Weight3.3kg

 
 
 
Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142