7Days Trend Review High Flow Nasal Cannula Device

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-70C
Minimum Order Quantity: 2 units
Price: negotiable
Packaging Details: main unit 50*41*33CM, trolley 85*63*24CM
Delivery Time: 5~8 work days
Payment Terms: L/C, T/T
Supply Ability: 1500 units/week
Detail Information
Oxygen Ajustment: Automatic Oxygen Range: 21%~100%
Flow: 10-70L/min Temperature: 31-37℃
Trend Review: 1,3,7 Days
High Light:

7Days Trend Review High Flow Nasal Cannula Device

,

Micomme Medical High Flow Nasal Cannula Device

,

7Days Trend Review high flow therapy devices


Product Description

 Micomme Medical 7Days Trend Review High Flow Nasal Cannula Device 70C

 

Description

A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.

 

HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.

 

HFNC is a heated and humidified system that allows prescribed fraction of inspired oxygen (FIO2) levels to be delivered at very high flow rates.

 

 

Application

When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!

 

The main physiological effects of HFNC are maintenance of a known stable alveolar FiO2, optimal humidification of the airway mucosa, reduction of the dead space, generation of a positive end-expiratory pressure (PEEP), ultimately yielding a reduction in the respiratory drive and in the work of breathing.

 

 

Advantage

In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.

 

In 2020, micomme ranked the sixth in export of medical respiratory devices in China.

 

 Automatic O2 concentration control technology

  • 21%~100% O2 concentration adjustable with 1% adjusting precision.
  • Built-in oxygen-gas mixture to accurately control oxygen and adjust oxygen concentration. 

 

 Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.

 

Effectively reduce the dead space with 70L/min high flow

 

7Days Trend Review High Flow Nasal Cannula Device 0

 

Specifications

Parameters OH-70C
Oxygen Adjustment Setting Automatic
Oxygen Adjustment Range 21%- 100%
Low flow mode 2- 25L/min
High flow mode 10- 70L/min
Temperature settings 31℃- 37℃
Real time display parameters Preset Flow, Preset FiO2, Preset Temperature, Treatment time
Trend review 1,3,7 days review
Content of review Flow, FiO2, Temperature, Treatment time
Presetting of treatment time Yes
Auto reminder of maintenance Yes
Main device disinfection No need disinfection for circuits system
Wipe disinfection for device surface
Screen

4.3 inches

Dimension 340*228*162mm
Weight 3.3kg
Alarm Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm,
temperature alarm, power down alarm, low ambient temperature alarm,
FiO2 not reaching preset value alarm, flow not reaching preset value
alarm, reaching preset treatment time alarm

 

 