Oxygen Ajustment: | Automatic | Oxygen Range: | 21%~100% |
---|---|---|---|
Flow: | 10-70L/min | Temperature: | 31-37℃ |
Trend Review: | 1,3,7 Days | ||
High Light: | Automatic high flow nasal oxygen therapy device,OH-70C high flow nasal oxygen therapy device,Hfnc Oh 70c |
Micomme user-friendly high flow nasal cannula oxygen therapy device 70C
Description
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.
HFNC is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. It is considered to have a number of physiological effects: it improves oxygenation, dynamic lung compliance, homogeneity and end expiratory lung volume; it decreases anatomical dead space and generates a positive airway pressure that can reduce respiratory rate, the work of breathing, and enhance patient comfort.
Application
Acute hypoxic respiratory failure (ARF) was the first condition treated with HFNC in adults. The use of heated and humidified high flow nasal cannula (HFNC) has become increasingly popular in the treatment of patients with acute respiratory failure through all age groups.
The use of HFNC in patients with Obstructive Sleep Apnea
Advantage
The first company to research, develop and produce high-flow in China.
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
Effectively reduce the dead space with 70L/min high flow.
Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.
Disposable heated tube and water chamber.
Specifications
Parameters | OH-70C |
Oxygen Adjustment Setting | Automatic |
Oxygen Adjustment Range | 21%- 100% |
Low flow mode | 2- 25L/min |
High flow mode | 10- 70L/min |
Temperature settings | 31℃- 37℃ |
Real time display parameters | Preset Flow, Preset FiO2, Preset Temperature, Treatment time |
Trend review | 1,3,7 days review |
Content of review | Flow, FiO2, Temperature, Treatment time |
Presetting of treatment time | Yes |
Auto reminder of maintenance | Yes |
Main device disinfection | No need disinfection for circuits system Wipe disinfection for device surface |
Screen |
4.3 inches |
Dimension | 340*228*162mm |
Weight | 3.3kg |
Alarm | Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching preset treatment time alarm |