Manual Nasal Cannula High Flow O2 Devices Micomme For Better Oxygenation

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-70C
Minimum Order Quantity: 10 units
Price: Negotiable
Packaging Details: 78*49*32CM/main unit ; 70*55*23.5CM/trolley
Delivery Time: 10 working days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Oxygen Adjustment: Manual Oxygen Range: 21%- 100%
Low Flow Mode: 2- 25L/min High Flow Mode: 10- 70L/min
Temperature Settings: 31℃~37℃ Screen: 4.3 Inches
Trend Review: 1、3、7 Days Review Dimension: 340*228*162mm
High Light:

Nasal Cannula High Flow O2 Devices

,

Micomme High Flow O2 Devices

,

Manual High Flow Oxygen Therapy Machine


Product Description

Micomme High Flow Nasal Cannula Oxygen Therapy Device For Better Oxygenation

 

Description

High-flow nasal cannula (HFNC) is a heated and humidified system that allows prescribed fraction of inspired oxygen (FIO2) levels to be delivered at very high flow rates. Let’s now consider how HFNC can help our patients improve their respiratory disease.

 

HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.

 

High-flow nasal cannula (HFNC) oxygen therapy comprises an air/oxygen blender, an active humidifier, a single heated circuit, and a nasal cannula. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% FiO2 at flow rates of up to 70 liters/min. The flow rate and FiO2 can be independently titrated based on your patient’s flow and FiO2 requirements.

 

 

Applications

 

  • HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.
  • HFNC also exerts its effect by providing some variable positive pressure. By providing variable positive pressure, use of high-flow nasal cannula (HFNC) increases functional residual capacity (FRC) by about 25% compared to use of traditional nasal cannula.
  • When HFNC is applied, the constant high flow of oxygen provides a washout of the anatomical dead space of the oropharynx and proximal tracheobronchial tree, which results in more efficient breathing.
  • In physiological terms, HFNO improves the fraction of inspired oxygen, washes and reduces dead space, generates positive end-expiratory pressure (PEEP) and provides more comfort than cold and dry oxygen.

 

 

 

Manual Nasal Cannula High Flow O2 Devices Micomme For Better Oxygenation 0

 

Advantage

The first company to research, develop and produce high-flow in China. Rich clinical application experience.

 

In 2020, micomme ranked the sixth in export of medical respiratory devices in China.

 

Patented one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.

 

Automatic O2 concentration control technology

  • 21%~100% O2 concentration adjustable with 1% adjusting precision.
  • Built-in oxygen-gas mixture to accurately control oxygen and adjust oxygen concentration.

 

Intelligent temperature and humidity control system

  • Providing air with core body temperature and 100% relative humidity
  • Adjustable temperature from 31℃ to 37℃

 

Manual Nasal Cannula High Flow O2 Devices Micomme For Better Oxygenation 1  Manual Nasal Cannula High Flow O2 Devices Micomme For Better Oxygenation 2

 

Specifications

 

 

Model OH-70C
Oxygen Adjustment Setting Automatic
Range 21%-100%

 

Flow

Low flow mode 2-25L/min
High flow mode 10-70L/min
Temperature settings 31℃-37℃
Real time monitoring parameters Flow, FiO2, Temperature, Treatment time

 

 

 

Data

Trend review 1,3,7 days review
Content of review Flow, FiO2, Temperature, Treatment time
Presetting of treatment time Yes

 

 

Management

Auto reminder of maintenance Yes
Main device disinfection

No need disinfection for circuits system

Wipe disinfection for device surface

Screen 4.3 inches
Dimension 340*228*162mm
Weight 3.3kg

 

 

 

Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, reaching present treatment time alarm

 