Oxygen Ajustment: | Manual | Oxygen Range: | 21%~100% |
---|---|---|---|
Flow: | 10-60L/min | Temperature: | 31℃,34℃,7℃ |
Trend Review: | 1,3,7 Days | ||
High Light: | CE Certified High Flow Oxygen Therapy Equipment,Comfortable High Flow Oxygen Therapy Equipment,CE Certified high flow oxygen therapy devices |
Micomme high flow nasal cannula device 60A with comfortable design
Description
High Flow Nasal Cannula (HFNC), isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’s flow and fi02 requirements.
HFNC is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. It is considered to have a number of physiological effects: it improves oxygenation, dynamic lung compliance, homogeneity and end expiratory lung volume; it decreases anatomical dead space and generates a positive airway pressure that can reduce respiratory rate, the work of breathing, and enhance patient comfort.
Application
The use of HFNC in patients with Hypercapnic Respiratory Failure, COPD.
The main physiological effects of HFNC are maintenance of a known stable alveolar FiO2, optimal humidification of the airway mucosa, reduction of the dead space, generation of a positive end-expiratory pressure (PEEP), ultimately yielding a reduction in the respiratory drive and in the work of breathing.
Advantage
The first company to research, develop and produce high-flow in China.
During the pandemic, micomme provided over 7000 units of devices globally.
Automatic O2 concentration control technology
Effectively reduce the dead space with 60L/min high flow
Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
Specifications
Parameters | OH-60A |
Oxygen Adjustment Setting | Manual |
Oxygen Adjustment Range | 21%- 100% |
Low flow mode | 2- 25L/min |
High flow mode | 10- 60L/min |
Temperature settings | 31℃,34℃,37℃, |
Real time display parameters | Preset Flow, Preset FiO2, Preset Temperature, Treatment time |
Trend review | 1,3,7 days review |
Content of review | Flow, FiO2, Temperature, Treatment time |
Presetting of treatment time | Yes |
Auto reminder of maintenance | Yes |
Main device disinfection | No need disinfection for circuits system Wipe disinfection for device surface |
Screen |
4.3 inches |
Dimension | 340*228*162mm |
Weight | 3.3kg |
Alarm | Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching preset treatment time alarm |