Oxygen Adjustment: | Manual | Oxygen Range: | 21%- 100% |
---|---|---|---|
Low Flow Mode: | 2- 25L/min | High Flow Mode: | 10- 60L/min |
Temperature Settings: | 31℃,34℃,37℃ | Screen: | 4.3 Inches |
Trend Review: | 1、3、7 Days Review | Dimension: | 340*228*162mm |
High Light: | Automatic High Flow Oxygen Therapy Machine,4.3inches Screen High Flow Oxygen Therapy Machin,Automatic high flow oxygen therapy devices |
Medical high flow nasal cannula device 60A
Description
High Flow Nasal Cannula is a heated and humidified system that allows prescribed fraction of inspired oxygen (FIO2) levels to be delivered at very high flow rates.
HFNC is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. It is considered to have a number of physiological effects: it improves oxygenation, dynamic lung compliance, homogeneity and end expiratory lung volume; it decreases anatomical dead space and generates a positive airway pressure that can reduce respiratory rate, the work of breathing, and enhance patient comfort.
Application
HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.
In physiological terms, HFNO improves the fraction of inspired oxygen, washes and reduces dead space, generates positive end-expiratory pressure (PEEP) and provides more comfort than cold and dry oxygen.
Advantage
During the pandemic, micomme provided over 7000 units of devices globally.
At present, micomme occupies over 50% market share in high flow filed in China.
Effectively reduce the dead space with 60L/min high flow
Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
Intelligent water-controlling system, automatically refills and maintains the optimal water level in the water chamber.
Specifications
Model | OH-60A | ||
Oxygen Adjustment | Setting | Manual | |
Range | 21%-100% | ||
| Low flow mode | 2-25L/min | |
High flow mode | 10-60L/min | ||
Temperature settings | 31℃,34℃,37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
| Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
| Auto reminder of maintenance | Yes | |
Main device disinfection | No need disinfection for circuits system | ||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
| Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm |