products

60L/Min Micomme High Flow Nasal Cannula Oxygen Therapy Device

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-60A
Minimum Order Quantity: 2 units
Price: negotiable
Packaging Details: main unit 50*41*33CM, trolley 85*63*24CM
Delivery Time: 5~8 work days
Payment Terms: L/C, T/T
Supply Ability: 1500 units/week
Detail Information
Oxygen Ajustment: Manual Oxygen Range: 21%~100%
Flow: 10-60L/min Temperature: 31℃,34℃37℃
Trend Review: 1,3,7 Days
High Light:

60L/Min High Flow Nasal Cannula Oxygen Therapy Device

,

Micomme High Flow Nasal Cannula Oxygen Therapy Device

,

Micomme high flow nasal cannula equipment


Product Description

Micomme user-friendly high flow nasal cannula oxygen therapy device 60A for home

 

Description

A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.

 

HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.

 

 

Application

HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.

 

The use of HFNC in patients with Post Surgical Respiratory Failure

 

 

Advantage

During the pandemic, micomme provided over 7000 units of devices globally.

 

At present, micomme occupies over 50% market share in high flow filed in China.

 

Temperature can be adjusted precisely.

 

Intelligent water-controlling system, automatically maintaining the optimal water level in the water chamber.

 

 Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.

 

60L/Min Micomme High Flow Nasal Cannula Oxygen Therapy Device 0

 

 

Specifications

Parameters OH-60A
Oxygen Adjustment Setting Manual
Oxygen Adjustment Range 21%- 100%
Low flow mode 2- 25L/min
High flow mode 10- 60L/min
Temperature settings 31℃,34℃,37℃
Real time display parameters Preset Flow, Preset FiO2, Preset Temperature, Treatment time
Trend review 1,3,7 days review
Content of review Flow, FiO2, Temperature, Treatment time
Presetting of treatment time Yes
Auto reminder of maintenance Yes
Main device disinfection No need disinfection for circuits system
Wipe disinfection for device surface
Screen

4.3 inches

Dimension 340*228*162mm
Weight 3.3kg
Alarm Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm,
temperature alarm, power down alarm, low ambient temperature alarm,
FiO2 not reaching preset value alarm, flow not reaching preset value
alarm, reaching preset treatment time alarm

 

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142