products

60L/Min High Flow Nasal Cannula At Home

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-60A
Minimum Order Quantity: 10 units
Price: Negotiable
Packaging Details: 78*49*32CM/main unit ; 70*55*23.5CM/trolley
Delivery Time: 10 working days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Oxygen Adjustment: Manual Oxygen Range: 21%- 100%
Low Flow Mode: 2- 25L/min High Flow Mode: 10- 60L/min
Temperature Settings: 31℃,34℃,37℃ Screen: 4.3 Inches
Trend Review: 1、3、7 Days Review Dimension: 340*228*162mm
High Light:

60L/Min High Flow Nasal Cannula At Home

,

Multi Mode High Flow Nasal Cannula At Home

,

60L/Min high flow oxygen at home


Product Description

Micomme high-performance heated humidified nasal cannula oxygen therapy device 60A
 
Description

HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.

 

HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.

 

 

Application

Its use has been widely explored, particularly in ICUs and emergency departments (EDs)

 

Other applications of HFNC include the prevention of postextubation hypoxaemia, pre-oxygenation before sedation/anaesthesia and oxygenation during bronchoscopy

 

 

Advantage

During the pandemic, micomme provided over 7000 units of devices globally.

 

At present, micomme occupies over 50% market share in high flow filed in China.

 

7 Days trend review: be able to check the use of the machine within 7 days, convenient for doctors to track the treatment of patients.

 

The machine uses timing function, which is convenient for nurses to charge by time.


60L/Min High Flow Nasal Cannula At Home 0  60L/Min High Flow Nasal Cannula At Home 1
 
Specifications

Model OH-60A
Oxygen Adjustment Setting Manual
Range 21%-100%

 
Flow

Low flow mode 2-25L/min
High flow mode 10-60L/min
Temperature settings 31℃,34℃,37℃
Real time monitoring parameters Flow, FiO2, Temperature, Treatment time

 
 
 
Data

Trend review 1,3,7 days review
Content of review Flow, FiO2, Temperature, Treatment time
Presetting of treatment time Yes

 
 
Management

Auto reminder of maintenance Yes
Main device disinfection

No need disinfection for circuits system
Wipe disinfection for device surface

Screen 4.3 inches
Dimension 340*228*162mm
Weight 3.3kg

 
 
 
Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142