Oxygen Adjustment: | Manual | Oxygen Range: | 21%- 100% |
---|---|---|---|
Low Flow Mode: | 2- 25L/min | High Flow Mode: | 10- 60L/min |
Temperature Settings: | 31℃,34℃,37℃ | Screen: | 4.3 Inches |
Trend Review: | 1、3、7 Days Review | Dimension: | 340*228*162mm |
High Light: | Heated Humidified High Flow Oxygen Devices For Home,CE Certified High Flow Oxygen Devices For Home,CE Certified high flow nasal cannula machine |
High flow nasal cannula device with oxygen therapy 60A for home-care
Description
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.
A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.
Application
Acute hypoxic respiratory failure (ARF) was the first condition treated with HFNC in adults. The use of heated and humidified high flow nasal cannula (HFNC) has become increasingly popular in the treatment of patients with acute respiratory failure through all age groups.
The use of HFNC in patients with Post Surgical Respiratory Failure.
Advantage
The first company to research, develop and produce high-flow in China.
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
Built-in oxygen-gas mixture to accurately control oxygen and adjust oxygen concentration.
Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
7 Days trend review: be able to check the use of the machine within 7 days, convenient for doctors to track the treatment of patients.
Specifications
Model | OH-60A | ||
Oxygen Adjustment | Setting | Manual | |
Range | 21%-100% | ||
|
Low flow mode | 2-25L/min | |
High flow mode | 10-60L/min | ||
Temperature settings | 31℃,34℃,37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
|
Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
|
Auto reminder of maintenance | Yes | |
Main device disinfection |
No need disinfection for circuits system |
||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
|
Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm |