Oxygen Adjustment: | Automatic | Oxygen Range: | 21%- 100% |
---|---|---|---|
Low Flow Mode: | 2- 25L/min | High Flow Mode: | 10- 70L/min |
Temperature Settings: | 31℃-37℃ | Screen: | 4.3 Inches |
Trend Review: | 1、3、7 Days Review | Dimension: | 340*228*162mm |
High Light: | Heated Humidified High Flow Oxygen Delivery Devices,Micomme Medical High Flow Oxygen Delivery Devices |
Micomme heated humidified nasal cannula oxygen therapy device 70C
Description
Humidified high flow nasal cannula therapy is a form of non-invasive respiratory support which has been compared to continuous positive airway pressure (CPAP).
HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.
Application
When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!
In physiological terms, HFNO improves the fraction of inspired oxygen, washes and reduces dead space, generates positive end-expiratory pressure (PEEP) and provides more comfort than cold and dry oxygen.
Advantage
The first company to research, develop and produce high-flow in China.
During the pandemic, micomme provided over 7000 units of devices globally
Automatic O2 concentration control technology
Effectively reduce the dead space with 70L/min high flow
Intelligent water-controlling system, automatically refills and maintains the optimal water level in the water chamber.
Specifications
Model | OH-70C | ||
Oxygen Adjustment | Setting | Automatic | |
Range | 21%-100% | ||
| Low flow mode | 2-25L/min | |
High flow mode | 10-70L/min | ||
Temperature settings | 31℃-37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
| Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
| Auto reminder of maintenance | Yes | |
Main device disinfection | No need disinfection for circuits system | ||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
| Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm |