Oxygen Ajustment: | Automatic | Oxygen Range: | 21%~100% |
---|---|---|---|
Flow: | 10-70L/min | Temperature: | 31-37℃ |
Trend Review: | 1,3,7 Days | ||
High Light: | Micomme High Flow Oxygen Therapy Equipment,Emergency Dept. High Flow Oxygen Therapy Equipment,Emergency Dept. high flow nasal oxygen device |
Micomme high flow nasal cannula device 70C with comfortable design
Description
HFNC is a heated and humidified system that allows prescribed fraction of inspired oxygen (FIO2) levels to be delivered at very high flow rates.
High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute.
High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute.
Application
When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!
HFNC also exerts its effect by providing some variable positive pressure. By providing variable positive pressure, use of high-flow nasal cannula (HFNC) increases functional residual capacity (FRC) by about 25% compared to use of traditional nasal cannula.
Advantage
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
In 2020, micomme ranked the sixth in export of medical respiratory devices in China.
Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.
The machine uses timing function, which is convenient for nurses to charge by time.
Disposable heated tube and water chamber.
Specifications
Parameters | OH-70C |
Oxygen Adjustment Setting | Automatic |
Oxygen Adjustment Range | 21%- 100% |
Low flow mode | 2- 25L/min |
High flow mode | 10- 70L/min |
Temperature settings | 31℃- 37℃ |
Real time display parameters | Preset Flow, Preset FiO2, Preset Temperature, Treatment time |
Trend review | 1,3,7 days review |
Content of review | Flow, FiO2, Temperature, Treatment time |
Presetting of treatment time | Yes |
Auto reminder of maintenance | Yes |
Main device disinfection | No need disinfection for circuits system Wipe disinfection for device surface |
Screen |
4.3 inches |
Dimension | 340*228*162mm |
Weight | 3.3kg |
Alarm | Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching preset treatment time alarm |