Oxygen Ajustment: | Manual | Oxygen Range: | 21%~100% |
---|---|---|---|
Flow: | 10-60L/min | Temperature: | 31℃,34℃,37℃ |
Trend Review: | 1,3,7 Days | ||
High Light: | Non Invasive High Flow Oxygen Therapy Devices,4.3Inches Screen High Flow Oxygen Therapy Devices,4.3Inches Screen high flow nasal oxygen machine |
Micomme high flow non-invasive respiratory therapy device 60A
Description
A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.
High Flow Nasal Cannula (HFNC), isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’s flow and fi02 requirements.
Application
HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.
The use of HFNC in patients with Post Surgical Respiratory Failure.
Advantage
At present, micomme occupies over 50% market share in high flow filed in China.
In 2020, micomme ranked the sixth in export of medical respiratory devices in China.
Effectively reduce the dead space with 60L/min high flow Intelligent water-controlling system, automatically refills and maintains the optimal water level in the water chamber.
Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.
The machine uses timing function, which is convenient for nurses to charge by time.
Specifications
Parameters | OH-60A |
Oxygen Adjustment Setting | Manual |
Oxygen Adjustment Range | 21%- 100% |
Low flow mode | 2- 25L/min |
High flow mode | 10- 60L/min |
Temperature settings | 31℃,34℃,37℃ |
Real time display parameters | Preset Flow, Preset FiO2, Preset Temperature, Treatment time |
Trend review | 1,3,7 days review |
Content of review | Flow, FiO2, Temperature, Treatment time |
Presetting of treatment time | Yes |
Auto reminder of maintenance | Yes |
Main device disinfection | No need disinfection for circuits system Wipe disinfection for device surface |
Screen |
4.3 inches |
Dimension | 340*228*162mm |
Weight | 3.3kg |
Alarm | Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching preset treatment time alarm |