VAT CPAP Trilogy Noninvasive Ventilator Low pressure Alarm

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: ST-30H
Minimum Order Quantity: 2 units
Price: Negotiable
Packaging Details: main unit 78*49*32CM trolley 70*55*23.5CM
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Color: White And Grey Mode: S/T, CPAP, S, T, PC, VAT
Screen Size: 5.7 Inch Color Screen Oxygen Concentration: 21%~100%, (increment By 1%)
Target Tidal Volume: 20~2500mL Backup BPM: 1~60BPM
Max Flow: 210L/min Max Leak Compensation: 90L/min
IPAP: 4~30cm H2O EPAP: 4~25cm H2O
CPAP: 4~20cm H2O
High Light:

CPAP Trilogy Noninvasive Ventilator

,

VAT Trilogy Noninvasive Ventilator

,

cpap non invasive ventilation


Product Description

Specifications
 

Parameter ST-30H
Ventilation mode S/T, CPAP, S, T, PC, VAT
Oxygen concentration 21%~100%, (increment by 1%)
Screen size 5.7 Inch color screen
Waveform display Pressure/flow
IPAP 4~30cm H2O
EPAP 4~25cm H2O
CPAP 4~20cm H2O
Target tidal volume 20~2500mL
Backup BPM 1~60BPM
Backup time 0.2~4.0S
Rise time 1~6 level
Ramp time 0~60min
Ramp pressure CPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief 1~3 level
Spontaneous Timin 0.2~4.0S
Spontaneous Timax 0.2~4.0S
I-Trigger setting Auto, 1~3 level
E-Trigger setting Auto, 1~3 level
Trigger lock Off, 0.3~1.5S
Flow of HFNC mode N/A
Max flow 210L/min
Max leak compensation 90L/min
Method of pressure measure The pressure testing tube is on mask side
Alarms

Apnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|

Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|

Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted

Apnea alarm range setting 0S, 10S, 20S, 30S
Disconnection alarm range setting 0S, 15S, 60S
Real-time monitoring data

Present oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|

Current leakage|Current volume|Trigger method

Other settings Screen lock|Display brightness| Flow|Pressure| Waveform
Backup battery 8 hours


Description

 

Noninvasive ventilation (NIV) supports the patient's breathing without the need for intubation or a tracheotomy. NIV delivers effective therapy with less risk of infection and improved survival in patients with respiratory failure.

 

Noninvasive ventilation supports the patient by delivering the right inspiratory and expiratory pressures or tidal volumes to support their individual ventilatory demand, enhancing alveolar minute ventilation and recruiting collapsed alveoli.

 

NIV works by creating a positive airway pressure - the pressure outside the lungs being greater than the pressure inside of the lungs. This causes air to be forced into the lungs (down the pressure gradient), lessening the respiratory effort and reducing the work of breathing.

 

Application

 

Chronic Obstruction Pulmonary Disease: The use of non-invasive ventilation (NIV) to support patients during acute decompensated respiratory failure secondary to an exacerbation of chronic obstructive pulmonary disease has unequivocal evidence of benefit in terms of reduction in the need for intubation, length of hospital stay and mortality.

 

Acute respiratory failure: Non-invasive mechanical ventilation has been increasingly used to avoid or serve as an alternative to intubation. Compared with medical therapy, and in some instances with invasive mechanical ventilation, it improves survival and reduces complications in selected patients with acute respiratory failure.
 
Better chance of survival: A meta-analysis suggested that NIV improved survival in acute care settings and that it is more beneficial when applied earlier rather than as a rescue therapy.
 
Reduced risk of infection: The use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections. A study has shown significantly more infectious complications related to the presence of the endotracheal tube.
 

VAT CPAP Trilogy Noninvasive Ventilator Low pressure Alarm 0
 
Advantage
 

Maximum inspiratory pressure: 30cm H2O, Max flow:210L/min.

 

AST-Automatic Sensitivity Technology provide the doctor convenience no need to set the sensitivity manually, and lower down patient’s respiratory power. Premium technology will monitor patients’ every single respiration, response immediately to synchronize patients’ breath through sensitivity trigger by detecting flow, pressure and waveform changing.

 

Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.

 


 

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142