Micomme High Flow Nasal Cannula Oxygen Therapy Device With 100% Relative Humidity

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-70C
Minimum Order Quantity: 10 units
Price: Negotiable
Packaging Details: 78*49*32CM/main unit ; 70*55*23.5CM/trolley
Delivery Time: 10 working days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Oxygen Adjustment: Manual Oxygen Range: 21%- 100%
Low Flow Mode: 2- 25L/min High Flow Mode: 10- 70L/min
Temperature Settings: 31℃~37℃ Screen: 4.3 Inches
Trend Review: 1、3、7 Days Review Dimension: 340*228*162mm
High Light:

Nasal Cannula Oxygen Therapy Device

,

Micomme Nasal Cannula Oxygen Therapy Device

,

100% Relative Humidity Hfnc Oxygen Machine


Product Description

Micomme High Flow Nasal Cannula Oxygen Therapy Device With 100% Relative Humidity Under 37℃

 

Description

HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort. A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.

 

HFNC is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. It is considered to have a number of physiological effects: it improves oxygenation, dynamic lung compliance, homogeneity and end expiratory lung volume; it decreases anatomical dead space and generates a positive airway pressure that can reduce respiratory rate, the work of breathing, and enhance patient comfort.

 

 

 

Applications
  • Acute hypoxic respiratory failure (ARF) was the first condition treated with HFNC in adults. The use of heated and humidified high flow nasal cannula (HFNC) has become increasingly popular in the treatment of patients with acute respiratory failure through all age groups.
  • HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.
  • Post Surgical Respiratory Failure
  • Acute Heart Failure /Pulmonary edema
  • Hypercapnic Respiratory Failure, COPD
  • Obstructive Sleep Apnea
  • Its use has been widely explored, particularly in ICUs and emergency departments (EDs)
  • Other applications of HFNC include the prevention of postextubation hypoxaemia, pre-oxygenation before sedation/anaesthesia and oxygenation during bronchoscopy

 

Micomme High Flow Nasal Cannula Oxygen Therapy Device With 100% Relative Humidity 0

 

Advantage

  • The first company to research, develop and produce high-flow in China. In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme. At present, micomme occupies over 50% market share in high flow filed in China.
  • Intelligent temperature and humidity control system
  • Providing air with core body temperature and 100% relative humidity
  • Adjustable temperature from 31℃ to 37℃
  • Effectively reduce the dead space with 70L/min high flow
  • Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
  • Intelligent water-controlling system, automatically refills and maintains the optimal water level in the water chamber.
  • Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.

 

 

Micomme High Flow Nasal Cannula Oxygen Therapy Device With 100% Relative Humidity 1  Micomme High Flow Nasal Cannula Oxygen Therapy Device With 100% Relative Humidity 2

 

Specifications

 

 

Model OH-70C
Oxygen Adjustment Setting Automatic
Range 21%-100%

 

Flow

Low flow mode 2-25L/min
High flow mode 10-70L/min
Temperature settings 31℃-37℃
Real time monitoring parameters Flow, FiO2, Temperature, Treatment time

 

 

 

Data

Trend review 1,3,7 days review
Content of review Flow, FiO2, Temperature, Treatment time
Presetting of treatment time Yes

 

 

Management

Auto reminder of maintenance Yes
Main device disinfection

No need disinfection for circuits system

Wipe disinfection for device surface

Screen 4.3 inches
Dimension 340*228*162mm
Weight 3.3kg

 

 

 

Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, reaching present treatment time alarm

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142