Oxygen Adjustment: | Manual | Oxygen Range: | 21%- 100% |
---|---|---|---|
Low Flow Mode: | 2- 25L/min | High Flow Mode: | 10- 70L/min |
Temperature Settings: | 31℃~37℃ | Screen: | 4.3 Inches |
Trend Review: | 1、3、7 Days Review | Dimension: | 340*228*162mm |
High Light: | High Flow Nasal Cannula Oxygen Therapy,Nasal Cannula Oxygen Therapy Micomme Device,Micomme Respiratory Support Oxygen Therapy Machine |
Description
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.
High-flow nasal cannula (HFNC) has become a frequently used non-invasive form of respiratory support in acute settings, however evidence supporting its use has only recently emerged.
High Flow Nasal Cannula (HFNC), isn't just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% FiO2 at flow rates of up to 70 liters/min. The flow rate and FiO2 can be independently titrated based on your patient's flow and FiO2 requirements.
Advantage
At present, micomme occupies over 50% market share in high flow filed in China.
During the pandemic, micomme provided over 7000 units of devices globally.
Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
Effectively reduce the dead space with 70L/min high flow.
Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.
Specifications
Model | OH-70C | ||
Oxygen Adjustment | Setting | Automatic | |
Range | 21%-100% | ||
Flow |
Low flow mode | 2-25L/min | |
High flow mode | 10-70L/min | ||
Temperature settings | 31℃-37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
Data |
Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
Management |
Auto reminder of maintenance | Yes | |
Main device disinfection |
No need disinfection for circuits system Wipe disinfection for device surface |
||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
Alarm |
Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, reaching present treatment time alarm |