Noninvasive Hospital Ventilator Machine / 4~25cm H2O Micomme Ventilator

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: ST-30H
Minimum Order Quantity: 2 units
Price: Negotiable
Packaging Details: main unit 78*49*32CM trolley 70*55*23.5CM
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Color: White And Grey Mode: S/T, CPAP, S, T, PC, VAT
Screen Size: 5.7 Inch Color Screen Oxygen Concentration: 21%~100%, (increment By 1%)
Target Tidal Volume: 20~2500mL Backup BPM: 1~60BPM
Max Flow: 210L/min Max Leak Compensation: 90L/min
IPAP: 4~30cm H2O EPAP: 4~25cm H2O
CPAP: 4~20cm H2O
High Light:

noninvasive hospital ventilator machine

,

Noninvasive micomme ventilator

,

25cm H2O Micomme Ventilator


Product Description

HOSPITAL VENTILATOR ST-30H with NON-INVASIVE VENTILATION SOLUTION

 
Description
 

Non-invasive ventilation (NIV) is the delivery of oxygen (ventilation support) via a face mask and therefore eliminating the need of an endotracheal airway. NIV achieves comparative physiological benefits to conventional mechanical ventilation by reducing the work of breathing and improving gas exchange.

 

Non-invasive ventilation (NIV) is ventilator support given to patients without the use of an endotracheal tube. It results in the potential complications of invasive mechanical ventilation being avoided. It also helps to deliver cost-effective therapy with decreased length of stay in the ICU and an improved chance of survival.

 

Application

 

Fewer complications: NIV reduces the number of possible complications by 62% and treatment errors by 50%.
 
Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.
 
Increased quality of life: NIV increases the quality of life for patients.
 

Reduced risk of infection: The use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections. A study has shown significantly more infectious complications related to the presence of the endotracheal tube.

 

Noninvasive Hospital Ventilator Machine / 4~25cm H2O Micomme Ventilator 0
 
Advantage
 

Automatic-Sensitivity technology provide the doctor convenience no need to set the sensitivity manually, and lower down patient’s respiratory power.
- Trigger sensitivity: support automatic trigger and 3 levels trigger sensitivity adjustment. The lower the trigger sensitivity is, the less work the patient needs to do to trigger, and the easier the ventilator is to trigger.
- Withdraw sensitivity: support automatic withdraw and 3-level withdraw sensitivity adjustment. The lower the sensitivity, the less work patients need to do to remove the ventilator, and the easier it is to remove the ventilator.

 
Leakage compensation performance, the device offers 90L/min maximum leakage compensation, it can also achieve a preset target pressure to form a pressure platform to complete accurate trigger and switch.


Noninvasive Hospital Ventilator Machine / 4~25cm H2O Micomme Ventilator 1

 
Specifications
 

ParameterST-30H
Ventilation modeS/T, CPAP, S, T, PC, VAT
Oxygen concentration21%~100%, (increment by 1%)
Screen size5.7 Inch color screen
Waveform displayPressure/flow
IPAP4~30cm H2O
EPAP4~25cm H2O
CPAP4~20cm H2O
Target tidal volume20~2500mL
Backup BPM1~60BPM
Backup time0.2~4.0S
Rise time1~6 level
Ramp time0~60min
Ramp pressureCPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief1~3 level
Spontaneous Timin0.2~4.0S
Spontaneous Timax0.2~4.0S
I-Trigger settingAuto, 1~3 level
E-Trigger settingAuto, 1~3 level
Trigger lockOff, 0.3~1.5S
Flow of HFNC modeN/A
Max flow210L/min
Max leak compensation90L/min
Method of pressure measureThe pressure testing tube is on mask side
AlarmsApnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted
Apnea alarm range setting0S, 10S, 20S, 30S
Disconnection alarm range setting0S, 15S, 60S
Real-time monitoring dataPresent oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
Other settingsScreen lock|Display brightness| Flow|Pressure| Waveform
Backup battery8 hours

 

Contact Details