Hospital Non Invasive Ventilator ST-30H With Automatic Oxygen Concentration Control

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: ST-30H
Minimum Order Quantity: 2 units
Price: Negotiable
Packaging Details: main unit 78*49*32CM trolley 70*55*23.5CM
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Color: White And Grey Mode: S/T, CPAP, S, T, PC, VAT
Screen Size: 5.7 Inch Color Screen Oxygen Concentration: 21%~100%, (increment By 1%)
Target Tidal Volume: 20~2500mL Backup BPM: 1~60BPM
Max Flow: 210L/min Max Leak Compensation: 90L/min
IPAP: 4~30cm H2O EPAP: 4~25cm H2O
CPAP: 4~20cm H2O
High Light:

Automatic Oxygen Control Non Invasive Ventilator

,

ST-30H Hospital Non Invasive Ventilator

,

Hospital Micomme Medical Ventilator


Product Description

MICOMME HIGH PERFORMANCE HOSPITAL NON-INVASIVE VENTILATOR ST-30H with ACCURATE OXYGEN CONCENTRATION CONTROL

 
Description
 

Noninvasive ventilation supports the patient by delivering the right inspiratory and expiratory pressures or tidal volumes to support their individual ventilatory demand, enhancing alveolar minute ventilation and recruiting collapsed alveoli.

 

Non-invasive ventilation (NIV) is the use of breathing support administered through a face mask, nasal mask, or a helmet. Air, usually with added oxygen, is given through the mask under positive pressure; generally the amount of pressure is alternated depending on whether someone is breathing in or out.

 

Application

 

Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.
 
Increased quality of life: NIV increases the quality of life for patients.
 
Better chance of survival: A meta-analysis suggested that NIV improved survival in acute care settings – and that it is more beneficial when applied earlier rather than as a rescue therapy.
 
Chronic Obstruction Pulmonary Disease: The use of non-invasive ventilation (NIV) to support patients during acute decompensated respiratory failure secondary to an exacerbation of chronic obstructive pulmonary disease has unequivocal evidence of benefit in terms of reduction in the need for intubation, length of hospital stay and mortality.

 

Hospital Non Invasive Ventilator ST-30H With Automatic Oxygen Concentration Control 0
 
Advantage
 

Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.
 

6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.
 
The pressure is measured on mask side. The pressure measuring hose is connected to the near pressure measuring port on the left side of the machine and the tee at the lower end of the mask (inside the package of the mask) to collect the pressure in the mask.

 
Hospital Non Invasive Ventilator ST-30H With Automatic Oxygen Concentration Control 1

 
Specifications
 

ParameterST-30H
Ventilation modeS/T, CPAP, S, T, PC, VAT
Oxygen concentration21%~100%, (increment by 1%)
Screen size5.7 Inch color screen
Waveform displayPressure/flow
IPAP4~30cm H2O
EPAP4~25cm H2O
CPAP4~20cm H2O
Target tidal volume20~2500mL
Backup BPM1~60BPM
Backup time0.2~4.0S
Rise time1~6 level
Ramp time0~60min
Ramp pressureCPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief1~3 level
Spontaneous Timin0.2~4.0S
Spontaneous Timax0.2~4.0S
I-Trigger settingAuto, 1~3 level
E-Trigger settingAuto, 1~3 level
Trigger lockOff, 0.3~1.5S
Flow of HFNC modeN/A
Max flow210L/min
Max leak compensation90L/min
Method of pressure measureThe pressure testing tube is on mask side
AlarmsApnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted
Apnea alarm range setting0S, 10S, 20S, 30S
Disconnection alarm range setting0S, 15S, 60S
Real-time monitoring dataPresent oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
Other settingsScreen lock|Display brightness| Flow|Pressure| Waveform
Backup battery8 hours

 

Contact Details