Color: | White And Grey | Mode: | S/T, CPAP, S, T, PC, VAT |
---|---|---|---|
Screen Size: | 5.7 Inch Color Screen | Oxygen Concentration: | 21%~100%, (increment By 1%) |
Target Tidal Volume: | 20~2500mL | Backup BPM: | 1~60BPM |
Max Flow: | 210L/min | Max Leak Compensation: | 90L/min |
IPAP: | 4~30cm H2O | EPAP: | 4~25cm H2O |
CPAP: | 4~20cm H2O | ||
High Light: | Automatic Oxygen Control Non Invasive Ventilator,ST-30H Hospital Non Invasive Ventilator,Hospital Micomme Medical Ventilator |
MICOMME HIGH PERFORMANCE HOSPITAL NON-INVASIVE VENTILATOR ST-30H with ACCURATE OXYGEN CONCENTRATION CONTROL
Description
Noninvasive ventilation supports the patient by delivering the right inspiratory and expiratory pressures or tidal volumes to support their individual ventilatory demand, enhancing alveolar minute ventilation and recruiting collapsed alveoli.
Non-invasive ventilation (NIV) is the use of breathing support administered through a face mask, nasal mask, or a helmet. Air, usually with added oxygen, is given through the mask under positive pressure; generally the amount of pressure is alternated depending on whether someone is breathing in or out.
Application
Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.
Increased quality of life: NIV increases the quality of life for patients.
Better chance of survival: A meta-analysis suggested that NIV improved survival in acute care settings – and that it is more beneficial when applied earlier rather than as a rescue therapy.
Chronic Obstruction Pulmonary Disease: The use of non-invasive ventilation (NIV) to support patients during acute decompensated respiratory failure secondary to an exacerbation of chronic obstructive pulmonary disease has unequivocal evidence of benefit in terms of reduction in the need for intubation, length of hospital stay and mortality.
Advantage
Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.
6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.
The pressure is measured on mask side. The pressure measuring hose is connected to the near pressure measuring port on the left side of the machine and the tee at the lower end of the mask (inside the package of the mask) to collect the pressure in the mask.
Specifications
|