products

210L/Min Non Invasive Ventilator Machine With Accurate Oxygen Concentration Control ST-30H

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: ST-30H
Minimum Order Quantity: 2 units
Price: Negotiable
Packaging Details: main unit 78*49*32CM trolley 70*55*23.5CM
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Color: White And Grey Mode: S/T, CPAP, S, T, PC, VAT
Screen Size: 5.7 Inch Color Screen Oxygen Concentration: 21%~100%, (increment By 1%)
Target Tidal Volume: 20~2500mL Backup BPM: 1~60BPM
Max Flow: 210L/min Max Leak Compensation: 90L/min
IPAP: 4~30cm H2O EPAP: 4~25cm H2O
CPAP: 4~20cm H2O
High Light:

210L/Min Non Invasive Ventilator Machine

,

210L/Min niv breathing machine

,

210L/Min noninvasive ventilator


Product Description

MICOMME HOSPITAL NON-INVASIVE VENTILATOR ST-30H with ACCURATE OXYGEN CONCENTRATION CONTROL

 
Description
 

Noninvasive ventilation supports the patient by delivering the right inspiratory and expiratory pressures or tidal volumes to support their individual ventilatory demand, enhancing alveolar minute ventilation and recruiting collapsed alveoli.

 

Noninvasive ventilation (NIV) supports the patient's breathing without the need for intubation or a tracheotomy. NIV delivers effective therapy with less risk of infection and improved survival in patients with respiratory failure.

 

Application
 

Chronic Obstruction Pulmonary Disease: The use of non-invasive ventilation (NIV) to support patients during acute decompensated respiratory failure secondary to an exacerbation of chronic obstructive pulmonary disease has unequivocal evidence of benefit in terms of reduction in the need for intubation, length of hospital stay and mortality.

 

Non-invasive mechanical ventilation has been increasingly used to avoid or serve as an alternative to intubation. Compared with medical therapy, and in some instances with invasive mechanical ventilation, it improves survival and reduces complications in selected patients with acute respiratory failure.

 

210L/Min Non Invasive Ventilator Machine With Accurate Oxygen Concentration Control ST-30H 0
 
Advantage
 

Max flow:210L/min
 
Maximum inspiratory pressure: 30cm H2O
 
Leakage compensation performance, the device offers 90L/min maximum leakage compensation, it can also achieve a preset target pressure to form a pressure platform to complete accurate trigger and switch.

 

Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.

 
210L/Min Non Invasive Ventilator Machine With Accurate Oxygen Concentration Control ST-30H 1

 
Specifications
 

ParameterST-30H
Ventilation modeS/T, CPAP, S, T, PC, VAT
Oxygen concentration21%~100%, (increment by 1%)
Screen size5.7 Inch color screen
Waveform displayPressure/flow
IPAP4~30cm H2O
EPAP4~25cm H2O
CPAP4~20cm H2O
Target tidal volume20~2500mL
Backup BPM1~60BPM
Backup time0.2~4.0S
Rise time1~6 level
Ramp time0~60min
Ramp pressureCPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief1~3 level
Spontaneous Timin0.2~4.0S
Spontaneous Timax0.2~4.0S
I-Trigger settingAuto, 1~3 level
E-Trigger settingAuto, 1~3 level
Trigger lockOff, 0.3~1.5S
Flow of HFNC modeN/A
Max flow210L/min
Max leak compensation90L/min
Method of pressure measureThe pressure testing tube is on mask side
AlarmsApnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted
Apnea alarm range setting0S, 10S, 20S, 30S
Disconnection alarm range setting0S, 15S, 60S
Real-time monitoring dataPresent oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
Other settingsScreen lock|Display brightness| Flow|Pressure| Waveform
Backup battery8 hours

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142