Oxygen Adjustment: | Manual | Oxygen Range: | 21%- 100% |
---|---|---|---|
Low Flow Mode: | 2- 25L/min | High Flow Mode: | 10- 60L/min |
Temperature Settings: | 31℃, 34℃,37℃ | Screen: | 4.3 Inches |
Trend Review: | 1、3、7 Days Review | Dimension: | 340*228*162mm |
High Light: | Against Covid-19 High Flow Oxygen Devices,high performance High Flow Oxygen Devices For Home,high performance high flow therapy machine |
Micomme HFNC device 60A for home
Description
High Flow Nasal Cannula (HFNC) is a heated and humidified system that allows prescribed fraction of inspired oxygen (FIO2) levels to be delivered at very high flow rates.
High Flow Nasal Cannula (HFNC) isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’s flow and fi02 requirements.
Application
When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!
When HFNC is applied, the constant high flow of oxygen provides a washout of the anatomical dead space of the oropharynx and proximal tracheobronchial tree, which results in more efficient breathing.
Advantage
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
During the pandemic, micomme provided over 7000 units of devices globally.
Automatic O2 concentration control technology
The machine uses timing function, which is convenient for nurses to charge by time.
Effectively reduce the dead space with 60L/min high flow
Specifications
Model | OH-60A | ||
Oxygen Adjustment | Setting | Manual | |
Range | 21%-100% | ||
|
Low flow mode | 2-25L/min | |
High flow mode | 10-60L/min | ||
Temperature settings | 31℃, 34℃,37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
|
Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
|
Auto reminder of maintenance | Yes | |
Main device disinfection |
No need disinfection for circuits system |
||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
|
Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm |