Oxygen Ajustment: | Automatic | Oxygen Range: | 21%~100% |
---|---|---|---|
Flow: | 10-70L/min | Temperature: | 31-37℃ |
Trend Review: | 1,3,7 Days | ||
High Light: | Adjustable Temperature High Flow Oxygen Therapy Machine,Adjustable Temperature high flow nasal oxygen therapy unit,High Flow Oxygen Therapy Machine Against Covid-19 |
Micomme OH Series high flow nasal cannula device 70C with comfortable design
Description
High Flow Nasal Cannula (HFNC) is a heated and humidified system that allows prescribed fraction of inspired oxygen (FIO2) levels to be delivered at very high flow rates.
High Flow Nasal Cannula (HFNC) isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’s flow and fi02 requirements.
Humidified high flow nasal cannula therapy is a form of non-invasive respiratory support which has been compared to continuous positive airway pressure (CPAP).
Application
HFNC also exerts its effect by providing some variable positive pressure. By providing variable positive pressure, use of high-flow nasal cannula (HFNC) increases functional residual capacity (FRC) by about 25% compared to use of traditional nasal cannula.
The main physiological effects of HFNC are maintenance of a known stable alveolar FiO2, optimal humidification of the airway mucosa, reduction of the dead space, generation of a positive end-expiratory pressure (PEEP), ultimately yielding a reduction in the respiratory drive and in the work of breathing.
Advantage
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
At present, micomme occupies over 50% market share in high flow filed in China.
Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.
The machine uses timing function, which is convenient for nurses to charge by time.
Disposable heated tube and water chamber.
Specifications
Parameters | OH-70C |
Oxygen Adjustment Setting | Automatic |
Oxygen Adjustment Range | 21%- 100% |
Low flow mode | 2- 25L/min |
High flow mode | 10- 70L/min |
Temperature settings | 31℃- 37℃ |
Real time display parameters | Preset Flow, Preset FiO2, Preset Temperature, Treatment time |
Trend review | 1,3,7 days review |
Content of review | Flow, FiO2, Temperature, Treatment time |
Presetting of treatment time | Yes |
Auto reminder of maintenance | Yes |
Main device disinfection | No need disinfection for circuits system Wipe disinfection for device surface |
Screen |
4.3 inches |
Dimension | 340*228*162mm |
Weight | 3.3kg |
Alarm | Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching preset treatment time alarm |