Oxygen Adjustment: | Automatic | Oxygen Range: | 21%- 100% |
---|---|---|---|
Low Flow Mode: | 2- 25L/min | High Flow Mode: | 10- 70L/min |
Temperature Settings: | 31℃-37℃ | Screen: | 4.3 Inches |
Trend Review: | 1、3、7 Days Review | Dimension: | 340*228*162mm |
High Light: | 70L/Min HFNC Oxygen Therapy Device,OH-70C HFNC Oxygen Therapy Device,Micomme Sepray Oh 70c |
Micomme medical OH Series HFNC device 70C
Description
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.
High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute.
HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.
Application
HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.
The use of HFNC in patients with Post Surgical Respiratory Failure.
Other applications of HFNC include the prevention of postextubation hypoxaemia, pre-oxygenation before sedation/anaesthesia and oxygenation during bronchoscopy.
Advantage
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
In 2020, micomme ranked the sixth in export of medical respiratory devices in China.
Automatic O2 concentration control technology
Effectively reduce the dead space with 70L/min high flow
Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
Specifications
Model | OH-70C | ||
Oxygen Adjustment | Setting | Automatic | |
Range | 21%-100% | ||
|
Low flow mode | 2-25L/min | |
High flow mode | 10-70L/min | ||
Temperature settings | 31℃-37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
|
Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
|
Auto reminder of maintenance | Yes | |
Main device disinfection |
No need disinfection for circuits system |
||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
|
Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm |