products

Micomme Sepray Oh 70c 70L/Min HFNC Oxygen Therapy Device

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-70C
Minimum Order Quantity: 10 units
Price: Negotiable
Packaging Details: 78*49*32CM/main unit ; 70*55*23.5CM/trolley
Delivery Time: 10 working days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Oxygen Adjustment: Automatic Oxygen Range: 21%- 100%
Low Flow Mode: 2- 25L/min High Flow Mode: 10- 70L/min
Temperature Settings: 31℃-37℃ Screen: 4.3 Inches
Trend Review: 1、3、7 Days Review Dimension: 340*228*162mm
High Light:

70L/Min HFNC Oxygen Therapy Device

,

OH-70C HFNC Oxygen Therapy Device

,

Micomme Sepray Oh 70c


Product Description

Micomme medical OH Series HFNC device 70C


Description
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.


High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute.


HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.
 
 

Application
HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.


The use of HFNC in patients with Post Surgical Respiratory Failure.


Other applications of HFNC include the prevention of postextubation hypoxaemia, pre-oxygenation before sedation/anaesthesia and oxygenation during bronchoscopy.
 
Micomme Sepray Oh 70c 70L/Min HFNC Oxygen Therapy Device 0
 
Advantage
 In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.

 

In 2020, micomme ranked the sixth in export of medical respiratory devices in China.

 

Automatic O2 concentration control technology

  • 21%~100% O2 concentration adjustable with 1% adjusting precision.
  • Built-in oxygen-gas mixture to accurately control oxygen and adjust oxygen concentration.

 

Effectively reduce the dead space with 70L/min high flow

 

Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.

 


Micomme Sepray Oh 70c 70L/Min HFNC Oxygen Therapy Device 1  Micomme Sepray Oh 70c 70L/Min HFNC Oxygen Therapy Device 2
 
Specifications
 

Model OH-70C
Oxygen Adjustment Setting Automatic
Range 21%-100%

 
Flow

Low flow mode 2-25L/min
High flow mode 10-70L/min
Temperature settings 31℃-37℃
Real time monitoring parameters Flow, FiO2, Temperature, Treatment time

 
 
 
Data

Trend review 1,3,7 days review
Content of review Flow, FiO2, Temperature, Treatment time
Presetting of treatment time Yes

 
 
Management

Auto reminder of maintenance Yes
Main device disinfection

No need disinfection for circuits system
Wipe disinfection for device surface

Screen 4.3 inches
Dimension 340*228*162mm
Weight 3.3kg

 
 
 
Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142