products

70L / Min High Flow Nasal Oxygen Therapy Unit

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-70C
Minimum Order Quantity: 2 units
Price: negotiable
Packaging Details: main unit 50*41*33CM, trolley 85*63*24CM
Delivery Time: 5~8 work days
Payment Terms: L/C, T/T
Supply Ability: 1500 units/week
Detail Information
Oxygen Ajustment: Automatic Oxygen Range: 21%~100%
Flow: 10-70L/min Temperature: 31-37℃
Trend Review: 1,3,7 Days
High Light:

70L / Min High Flow Nasal Oxygen Therapy Unit

,

70L / Min High Flow Oxygen Equipment

,

70L / Min high flow oxygen delivery system


Product Description

Micomme OH-Series high flow nasal cannula HFNC oxygen therapy device 70C

 

Description

HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.

 

High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute.

 

A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.

 

 

Application

Its use has been widely explored, particularly in ICUs and emergency departments (EDs)

 

The main physiological effects of HFNC are maintenance of a known stable alveolar FiO2, optimal humidification of the airway mucosa, reduction of the dead space, generation of a positive end-expiratory pressure (PEEP), ultimately yielding a reduction in the respiratory drive and in the work of breathing.

 

 

Advantage

The first company to research, develop and produce high-flow in China.

 

At present, micomme occupies over 50% market share in high flow filed in China.

 

 Automatic O2 concentration control technology

  • 21%~100% O2 concentration adjustable with 1% adjusting precision.
  • Built-in oxygen-gas mixture to accurately control oxygen and adjust oxygen concentration. 

 

Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.

 

 Effectively reduce the dead space with 70L/min high flow

 

70L / Min High Flow Nasal Oxygen Therapy Unit 0

 

 

Specifications

Parameters OH-70C
Oxygen Adjustment Setting Automatic
Oxygen Adjustment Range 21%- 100%
Low flow mode 2- 25L/min
High flow mode 10- 70L/min
Temperature settings 31℃- 37℃
Real time display parameters Preset Flow, Preset FiO2, Preset Temperature, Treatment time
Trend review 1,3,7 days review
Content of review Flow, FiO2, Temperature, Treatment time
Presetting of treatment time Yes
Auto reminder of maintenance Yes
Main device disinfection No need disinfection for circuits system
Wipe disinfection for device surface
Screen

4.3 inches

Dimension 340*228*162mm
Weight 3.3kg
Alarm Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm,
temperature alarm, power down alarm, low ambient temperature alarm,
FiO2 not reaching preset value alarm, flow not reaching preset value
alarm, reaching preset treatment time alarm

 

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142