Perfect combination of NIV and HFNC ventilation solution with ST-30K

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: ST-30K
Minimum Order Quantity: 2 units
Price: Negotiable
Packaging Details: main unit 78*49*32CM trolley 70*55*23.5CM
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Screen Size: 5.7 Inch Color Screen Oxygen Concentration: 21%~100%, (increment By 1%)
Target Tidal Volume: 20~2500mL Backup BPM: 1~60BPM
Flow Of HFNC Mode: 10~70L/min Max Flow: 300L/min
Max Leak Compensation: 120L/min IPAP: 4~40cm H2O
EPAP: 4~25cm H2O CPAP: 4~20cm H2O

Product Description

PERFECT COMBINATION of NIV and HFNC VENTILATION SOLUTION with ST-30K

 

Description

 

The patients with known or suspected COVID-19 with respiratory failure should be intubated and ventilated early in the disease course without the option for less invasive treatments, including non-invasive ventilation (NIV).

 

Non-invasive ventilation (NIV) is ventilator support given to patients without the use of an endotracheal tube. It results in the potential complications of invasive mechanical ventilation being avoided. It also helps to deliver cost-effective therapy with decreased length of stay in the ICU and an improved chance of survival.

 

Application

 

Increased quality of life: NIV increases the quality of life for patients.

 

Better chance of survival: A meta-analysis suggested that NIV improved survival in acute care settings – and that it is more beneficial when applied earlier rather than as a rescue therapy.

 

Reduced risk of infection: The use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections. A study has shown significantly more infectious complications related to the presence of the endotracheal tube.

Perfect combination of NIV and HFNC ventilation solution with ST-30K 0

 

Advantage

 

HFNC (High Flow) mode, 21~100% FiO2, 31~40℃, 10~70L/min air oxygen mixture of humidified gas.

 

6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.

 

AST-Premium technology will monitor patients’ every single respiration, response immediately to synchronize patients’ breath through sensitivity trigger by detecting flow, pressure and waveform changing.

 

Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.

 

Perfect combination of NIV and HFNC ventilation solution with ST-30K 1

 

Specifications

 

Parameter ST-30K
Ventilation mode S/T, CPAP, S, T, PC, VAT, HFNC
Oxygen concentration 21%~100%, (increment by 1%)
Screen size 5.7 Inch color screen
Waveform display Pressure/flow
IPAP 4~40cm H2O
EPAP 4~25cm H2O
CPAP 4~20cm H2O
Target tidal volume 20~2500mL
Backup BPM 1~60BPM
Backup time 0.2~4.0S
Rise time 1~6 level
Ramp time 0~60min
Ramp pressure CPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief 1~3 level
Spontaneous Timin 0.2~4.0S
Spontaneous Timax 0.2~4.0S
I-Trigger setting Auto, 1~3 level
E-Trigger setting Auto, 1~3 level
Trigger lock Off, 0.3~1.5S
Flow of HFNC mode 10~70L/min
Max flow 300L/min
Max leak compensation 120L/min
Method of pressure measure The pressure testing tube is on mask side
Alarms Apnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted
Apnea alarm range setting 0S, 10S, 20S, 30S
Disconnection alarm range setting 0S, 15S, 60S
Real-time monitoring data Present oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
Other settings Screen lock|Display brightness| Flow| Pressure| Waveform| Event summary
Backup battery 8 hours

 