products

6 Level Rise Time Non Invasive Ventilator Machine for emergency dept.

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: ST-30K
Minimum Order Quantity: 2 units
Price: Negotiable
Packaging Details: main unit 78*49*32CM trolley 70*55*23.5CM
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Color: White And Grey Mode: S/T, CPAP, S, T, PC, VAT, HFNC
Screen Size: 5.7 Inch Color Screen Oxygen Concentration: 21%~100%, (increment By 1%)
Target Tidal Volume: 20~2500mL Backup BPM: 1~60BPM
Flow Of HFNC Mode: 10~70L/min Max Flow: 300L/min
Max Leak Compensation: 120L/min IPAP: 4~40cm H2O
EPAP: 4~25cm H2O CPAP: 4~20cm H2O
High Light:

6 Level Rise Time Non Invasive Ventilator Machine

,

Non Invasive Ventilator Machine For Emergency Dept.

,

6 Level Rise Time niv machine


Product Description

HIGH PERFORMANCE HOSPITAL NON-INVASIVE VENTILATION with ST-30K

 

Description

 

Non-invasive ventilation (NIV) is the delivery of oxygen (ventilation support) via a face mask and therefore eliminating the need of an endotracheal airway. NIV achieves comparative physiological benefits to conventional mechanical ventilation by reducing the work of breathing and improving gas exchange.

 

Non-invasive ventilation (NIV) refers to the provision of ventilatory support through the patient's upper airway using a mask or similar device.

 

Application

 

The patients with known or suspected COVID-19 with respiratory failure should be intubated and ventilated early in the disease course without the option for less invasive treatments, including non-invasive ventilation (NIV).

 

Fewer complications: NIV reduces the number of possible complications by 62% and treatment errors by 50%.

 

Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.

 

6 Level Rise Time Non Invasive Ventilator Machine for emergency dept. 0

 

Advantage

 

Leakage compensation performance, the device offers 120 L/min maximum leakage compensation, it can also achieve a preset target pressure to form a pressure platform to complete accurate trigger and switch.

 

HFNC (High Flow) mode, 21~100% FiO2, 31~40℃, 10~70L/min air oxygen mixture of humidified gas.

 

6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.

 

Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.

 

6 Level Rise Time Non Invasive Ventilator Machine for emergency dept. 1

 

Specifications

 

Parameter ST-30K
Ventilation mode S/T, CPAP, S, T, PC, VAT, HFNC
Oxygen concentration 21%~100%, (increment by 1%)
Screen size 5.7 Inch color screen
Waveform display Pressure/flow
IPAP 4~40cm H2O
EPAP 4~25cm H2O
CPAP 4~20cm H2O
Target tidal volume 20~2500mL
Backup BPM 1~60BPM
Backup time 0.2~4.0S
Rise time 1~6 level
Ramp time 0~60min
Ramp pressure CPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief 1~3 level
Spontaneous Timin 0.2~4.0S
Spontaneous Timax 0.2~4.0S
I-Trigger setting Auto, 1~3 level
E-Trigger setting Auto, 1~3 level
Trigger lock Off, 0.3~1.5S
Flow of HFNC mode 10~70L/min
Max flow 300L/min
Max leak compensation 120L/min
Method of pressure measure The pressure testing tube is on mask side
Alarms Apnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted
Apnea alarm range setting 0S, 10S, 20S, 30S
Disconnection alarm range setting 0S, 15S, 60S
Real-time monitoring data Present oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
Other settings Screen lock|Display brightness| Flow| Pressure| Waveform| Event summary
Backup battery 8 hours

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142