products

High Performance Hospital Non Invasive Ventilator ST-30K With HFNC Solution

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: ST-30K
Minimum Order Quantity: 2 units
Price: Negotiable
Packaging Details: main unit 78*49*32CM trolley 70*55*23.5CM
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Color: White And Grey Mode: S/T, CPAP, S, T, PC, VAT, HFNC
Screen Size: 5.7 Inch Color Screen Oxygen Concentration: 21%~100%, (increment By 1%)
Target Tidal Volume: 20~2500mL Backup BPM: 1~60BPM
Flow Of HFNC Mode: 10~70L/min Max Flow: 300L/min
Max Leak Compensation: 120L/min IPAP: 4~40cm H2O
EPAP: 4~25cm H2O CPAP: 4~20cm H2O
High Light:

Hospital Non Invasive Ventilator

,

HFNC Non Invasive Ventilator

,

niv bipap


Product Description

HIGH PERFORMANCE HOSPITAL NON-INVASIVE VENTILATOR ST-30K with HFNC SOLUTION

 

Description

 

Non-invasive ventilation (NIV) refers to the provision of ventilatory support through the patient's upper airway using a mask or similar device.

 

Non-invasive ventilation (NIV) is the use of breathing support administered through a face mask, nasal mask, or a helmet. Air, usually with added oxygen, is given through the mask under positive pressure; generally the amount of pressure is alternated depending on whether someone is breathing in or out.

 

Application

 

Better chance of survival: A meta-analysis suggested that NIV improved survival in acute care settings – and that it is more beneficial when applied earlier rather than as a rescue therapy.

 

Reduced risk of infection: The use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections. A study has shown significantly more infectious complications related to the presence of the endotracheal tube.

 

Non-invasive ventilation (NIV) refers to the provision of ventilatory support through the patient's upper airway using a mask or similar device.

High Performance Hospital Non Invasive Ventilator ST-30K With HFNC Solution 0

 

Advantage

 

HFNC (High Flow) mode, 21~100% FiO2, 31~40℃, 10~70L/min air oxygen mixture of humidified gas.

 

6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.

 

The pressure is measured on mask side. The pressure measuring hose is connected to the near pressure measuring port on the left side of the machine and the tee at the lower end of the mask (inside the package of the mask) to collect the pressure in the mask.

 

5.7-inch LCD color screen, flow rate and pressure double waveform, setting, alarm, treatment information displayed on the screen, combined with a knob. A single page can complete all settings.

 

High Performance Hospital Non Invasive Ventilator ST-30K With HFNC Solution 1

 

Specifications

 

Parameter ST-30K
Ventilation mode S/T, CPAP, S, T, PC, VAT, HFNC
Oxygen concentration 21%~100%, (increment by 1%)
Screen size 5.7 Inch color screen
Waveform display Pressure/flow
IPAP 4~40cm H2O
EPAP 4~25cm H2O
CPAP 4~20cm H2O
Target tidal volume 20~2500mL
Backup BPM 1~60BPM
Backup time 0.2~4.0S
Rise time 1~6 level
Ramp time 0~60min
Ramp pressure CPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief 1~3 level
Spontaneous Timin 0.2~4.0S
Spontaneous Timax 0.2~4.0S
I-Trigger setting Auto, 1~3 level
E-Trigger setting Auto, 1~3 level
Trigger lock Off, 0.3~1.5S
Flow of HFNC mode 10~70L/min
Max flow 300L/min
Max leak compensation 120L/min
Method of pressure measure The pressure testing tube is on mask side
Alarms Apnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted
Apnea alarm range setting 0S, 10S, 20S, 30S
Disconnection alarm range setting 0S, 15S, 60S
Real-time monitoring data Present oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
Other settings Screen lock|Display brightness| Flow| Pressure| Waveform| Event summary
Backup battery 8 hours

 

Contact Details