products

1~60BPM Non Invasive Ventilation Equipment For Respiratory Dept.

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: ST-30K
Minimum Order Quantity: 2 units
Price: Negotiable
Packaging Details: main unit 78*49*32CM trolley 70*55*23.5CM
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Color: White And Grey Mode: S/T, CPAP, S, T, PC, VAT, HFNC
Screen Size: 5.7 Inch Color Screen Oxygen Concentration: 21%~100%, (increment By 1%)
Target Tidal Volume: 20~2500mL Backup BPM: 1~60BPM
Flow Of HFNC Mode: 10~70L/min Max Flow: 300L/min
Max Leak Compensation: 120L/min IPAP: 4~40cm H2O
EPAP: 4~25cm H2O CPAP: 4~20cm H2O
High Light:

60BPM Non Invasive Ventilation Equipment

,

Non Invasive Ventilation Equipment For Respiratory Dept.

,

60BPM cpap ventilator machine


Product Description

HIGH PERFORMANCE HOSPITAL NON-INVASIVE VENTILATOR ST-30K with HFNC SOLUTION

 

Description

 

Non-invasive ventilation (NIV) is the use of breathing support administered through a face mask, nasal mask, or a helmet. Air, usually with added oxygen, is given through the mask under positive pressure; generally the amount of pressure is alternated depending on whether someone is breathing in or out.

 

Non-invasive ventilation (NIV) refers to the provision of ventilatory support through the patient's upper airway using a mask or similar device.

 

Application

 

Acute respiratory distress syndrome (ARDS) is characterised by acute onset respiratory failure, diffuse pulmonary opacities and severe hypoxemia. The use of NIV can help to avoid such complications such as a higher incidence of ventilator-associated pneumonia and barotrauma.

 

Fewer complications: NIV reduces the number of possible complications by 62% and treatment errors by 50%.

 

Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.

1~60BPM Non Invasive Ventilation Equipment For Respiratory Dept. 0

 

Advantage

 

- Trigger sensitivity: support automatic trigger and 3 levels trigger sensitivity adjustment. The lower the trigger sensitivity is, the less work the patient needs to do to trigger, and the easier the ventilator is to trigger.

- Withdraw sensitivity: support automatic withdraw and 3-level withdraw sensitivity adjustment. The lower the sensitivity, the less work patients need to do to remove the ventilator, and the easier it is to remove the ventilator.

 

The pressure is measured on mask side. The pressure measuring hose is connected to the near pressure measuring port on the left side of the machine and the tee at the lower end of the mask (inside the package of the mask) to collect the pressure in the mask.

 

1~60BPM Non Invasive Ventilation Equipment For Respiratory Dept. 1

 

Specifications

 

Parameter ST-30K
Ventilation mode S/T, CPAP, S, T, PC, VAT, HFNC
Oxygen concentration 21%~100%, (increment by 1%)
Screen size 5.7 Inch color screen
Waveform display Pressure/flow
IPAP 4~40cm H2O
EPAP 4~25cm H2O
CPAP 4~20cm H2O
Target tidal volume 20~2500mL
Backup BPM 1~60BPM
Backup time 0.2~4.0S
Rise time 1~6 level
Ramp time 0~60min
Ramp pressure CPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief 1~3 level
Spontaneous Timin 0.2~4.0S
Spontaneous Timax 0.2~4.0S
I-Trigger setting Auto, 1~3 level
E-Trigger setting Auto, 1~3 level
Trigger lock Off, 0.3~1.5S
Flow of HFNC mode 10~70L/min
Max flow 300L/min
Max leak compensation 120L/min
Method of pressure measure The pressure testing tube is on mask side
Alarms Apnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted
Apnea alarm range setting 0S, 10S, 20S, 30S
Disconnection alarm range setting 0S, 15S, 60S
Real-time monitoring data Present oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
Other settings Screen lock|Display brightness| Flow| Pressure| Waveform| Event summary
Backup battery 8 hours

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142