Color: | White And Grey | Mode: | S/T, CPAP, S, T, PC, VAT, HFNC |
---|---|---|---|
Screen Size: | 5.7 Inch Color Screen | Oxygen Concentration: | 21%~100%, (increment By 1%) |
Target Tidal Volume: | 20~2500mL | Backup BPM: | 1~60BPM |
Flow Of HFNC Mode: | 10~70L/min | Max Flow: | 300L/min |
Max Leak Compensation: | 120L/min | IPAP: | 4~40cm H2O |
EPAP: | 4~25cm H2O | CPAP: | 4~20cm H2O |
High Light: | multi mode Non Invasive Ventilator Machine,Class I Non Invasive Ventilator Machine,multi mode non invasive ventilation device |
HIGH PERFORMANCE NON-INVASIVE VENTILATOR ST-30K with HFNC SOLUTION for HOSPITAL USE
Description
Non-invasive ventilation (NIV) is the use of breathing support administered through a face mask, nasal mask, or a helmet. Air, usually with added oxygen, is given through the mask under positive pressure; generally the amount of pressure is alternated depending on whether someone is breathing in or out.
Non-invasive ventilation (NIV) is the delivery of oxygen (ventilation support) via a face mask and therefore eliminating the need of an endotracheal airway. NIV achieves comparative physiological benefits to conventional mechanical ventilation by reducing the work of breathing and improving gas exchange.
Application
Acute respiratory distress syndrome (ARDS) is characterised by acute onset respiratory failure, diffuse pulmonary opacities and severe hypoxemia. The use of NIV can help to avoid such complications such as a higher incidence of ventilator-associated pneumonia and barotrauma.
The patients with known or suspected COVID-19 with respiratory failure should be intubated and ventilated early in the disease course without the option for less invasive treatments, including non-invasive ventilation (NIV).
Advantage
- Trigger sensitivity: support automatic trigger and 3 levels trigger sensitivity adjustment. The lower the trigger sensitivity is, the less work the patient needs to do to trigger, and the easier the ventilator is to trigger.
- Withdraw sensitivity: support automatic withdraw and 3-level withdraw sensitivity adjustment. The lower the sensitivity, the less work patients need to do to remove the ventilator, and the easier it is to remove the ventilator.
Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.
Specifications
|