Color: | White And Grey | Mode: | S/T, CPAP, S, T, PC, VAT, HFNC |
---|---|---|---|
Screen Size: | 5.7 Inch Color Screen | Oxygen Concentration: | 21%~100%, (increment By 1%) |
Target Tidal Volume: | 20~2500mL | Backup BPM: | 1~60BPM |
Flow Of HFNC Mode: | 10~70L/min | Max Flow: | 300L/min |
Max Leak Compensation: | 120L/min | IPAP: | 4~40cm H2O |
EPAP: | 4~25cm H2O | CPAP: | 4~20cm H2O |
High Light: | Hospital ICU Non Invasive Ventilator Machine,300L/Min Flow Non Invasive Ventilator Machine,300L/Min Flow noninvasive ventilator |
HIGH PERFORMANCE NON-INVASIVE VENTILATOR ST-30K with HFNC MODE for HOSPITAL USE
Description
Non-invasive ventilation (NIV) supports the patient's breathing without the need for intubation or a tracheotomy. NIV delivers effective therapy with less risk of infection and improved survival in patients with respiratory failure.
Non-invasive ventilation supports the patient by delivering the right inspiratory and expiratory pressures or tidal volumes to support their individual ventilatory demand, enhancing alveolar minute ventilation and recruiting collapsed alveoli.
Application
Chronic Obstruction Pulmonary Disease: The use of non-invasive ventilation (NIV) to support patients during acute decompensated respiratory failure secondary to an exacerbation of chronic obstructive pulmonary disease has unequivocal evidence of benefit in terms of reduction in the need for intubation, length of hospital stay and mortality.
Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.
Increased quality of life: NIV increases the quality of life for patients.
Advantage
AST-Premium technology will monitor patients’ every single respiration, response immediately to synchronize patients’ breath through sensitivity trigger by detecting flow, pressure and waveform changing.
Leakage compensation performance, the device offers 120 L/min maximum leakage compensation, it can also achieve a preset target pressure to form a pressure platform to complete accurate trigger and switch.
HFNC (High Flow) mode, 21~100% FiO2, 31~40℃, 10~70L/min air oxygen mixture of humidified gas.
Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.
Specifications
|