Oxygen Adjustment: | Automatic | Oxygen Range: | 21%- 100% |
---|---|---|---|
Low Flow Mode: | 2- 25L/min | High Flow Mode: | 10- 70L/min |
Temperature Settings: | 31℃-37℃ | Screen: | 4.3 Inches |
Trend Review: | 1、3、7 Days Review | Dimension: | 340*228*162mm |
High Light: | HFNC High Flow Nasal Oxygen Therapy Device,70L/Min High Flow Nasal Oxygen Therapy Device |
Micomme medical high flow device with oxygen therapy 70C
Description
HFNC is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems.
It is considered to have a number of physiological effects: it improves oxygenation, dynamic lung compliance, homogeneity and end expiratory lung volume; it decreases anatomical dead space and generates a positive airway pressure that can reduce respiratory rate, the work of breathing, and enhance patient comfort.
Application
When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!
HFNC also exerts its effect by providing some variable positive pressure. By providing variable positive pressure, use of high-flow nasal cannula (HFNC) increases functional residual capacity (FRC) by about 25% compared to use of traditional nasal cannula.
Advantage
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
During the pandemic, micomme provided over 7000 units of devices globally.
Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
Intelligent water-controlling system, automatically refills and maintains the optimal water level in the water chamber.
Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.
Specifications
Model | OH-70C | ||
Oxygen Adjustment | Setting | Automatic | |
Range | 21%-100% | ||
| Low flow mode | 2-25L/min | |
High flow mode | 10-70L/min | ||
Temperature settings | 31℃-37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
| Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
| Auto reminder of maintenance | Yes | |
Main device disinfection | No need disinfection for circuits system | ||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
| Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm |