Oxygen Adjustment: | Automatic | Oxygen Range: | 21%- 100% |
---|---|---|---|
Low Flow Mode: | 2- 25L/min | High Flow Mode: | 10- 70L/min |
Temperature Settings: | 31℃-37℃ | Screen: | 4.3 Inches |
Trend Review: | 1、3、7 Days Review | Dimension: | 340*228*162mm |
High Light: | heated humidified high flow nasal cannula oxygen therapy device,70L/Min high flow o2 nasal cannula device |
Micomme OH Series heated humidified nasal cannula oxygen therapy device 70C
Description
HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.
High-flow nasal cannula (HFNC) therapy is an oxygen supply system capable of delivering up to 100% humidified and heated oxygen at a high flow rate per minute.
Humidified high flow nasal cannula therapy is a form of non-invasive respiratory support which has been compared to continuous positive airway pressure (CPAP).
Application
The use of HFNC in patients with Hypercapnic Respiratory Failure, COPD.
HFNC also exerts its effect by providing some variable positive pressure. By providing variable positive pressure, use of high-flow nasal cannula (HFNC) increases functional residual capacity (FRC) by about 25% compared to use of traditional nasal cannula.
Advantage
At present, micomme occupies over 50% market share in high flow filed in China.
In 2020, micomme ranked the sixth in export of medical respiratory devices in China.
Automatic O2 concentration control technology
Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.
The machine uses timing function, which is convenient for nurses to charge by time.
Specifications
Model | OH-70C | ||
Oxygen Adjustment | Setting | Automatic | |
Range | 21%-100% | ||
| Low flow mode | 2-25L/min | |
High flow mode | 10-70L/min | ||
Temperature settings | 31℃-37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
| Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
| Auto reminder of maintenance | Yes | |
Main device disinfection | No need disinfection for circuits system | ||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
| Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm |