1~60BPM 300L/Min Hospital Respirator Machine niv equipment

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: ST-30K
Minimum Order Quantity: 2 units
Price: Negotiable
Packaging Details: main unit 78*49*32CM trolley 70*55*23.5CM
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Screen Size: 5.7 Inch Color Screen Oxygen Concentration: 21%~100%, (increment By 1%)
Target Tidal Volume: 20~2500mL Backup BPM: 1~60BPM
Flow Of HFNC Mode: 10~70L/min Max Flow: 300L/min
Max Leak Compensation: 120L/min IPAP: 4~40cm H2O
EPAP: 4~25cm H2O CPAP: 4~20cm H2O
High Light:

300L/min hospital respirator machine

,

300L/min niv equipment

,

60BPM Niv Equipment


Product Description

HOSPITAL NON-INVASIVE VENTILATOR ST-30K with HIGH PERFORMANCE

1~60BPM 300L/Min Hospital Respirator Machine niv equipment 0

 

Description

 

Non-invasive ventilation (NIV) is the use of breathing support administered through a face mask, nasal mask, or a helmet. Air, usually with added oxygen, is given through the mask under positive pressure; generally the amount of pressure is alternated depending on whether someone is breathing in or out.

 

Non-invasive ventilation (NIV) is ventilator support given to patients without the use of an endotracheal tube. It results in the potential complications of invasive mechanical ventilation being avoided. It also helps to deliver cost-effective therapy with decreased length of stay in the ICU and an improved chance of survival.

 

Application

 

Fewer complications: NIV reduces the number of possible complications by 62% and treatment errors by 50%.

 

Acute respiratory failure: Non-invasive mechanical ventilation has been increasingly used to avoid or serve as an alternative to intubation. Compared with medical therapy, and in some instances with invasive mechanical ventilation, it improves survival and reduces complications in selected patients with acute respiratory failure.

 

Better chance of survival: A meta-analysis suggested that NIV improved survival in acute care settings – and that it is more beneficial when applied earlier rather than as a rescue therapy.

 

 

1~60BPM 300L/Min Hospital Respirator Machine niv equipment 1

 

Advantage

 

Max flow:300L/min

 

Maximum inspiratory pressure: 40cm H2O

 

The pressure is measured on mask side. The pressure measuring hose is connected to the near pressure measuring port on the left side of the machine and the tee at the lower end of the mask (inside the package of the mask) to collect the pressure in the mask.

 

Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.

 

Specifications

 

Parameter ST-30K
Ventilation mode S/T, CPAP, S, T, PC, VAT, HFNC
Oxygen concentration 21%~100%, (increment by 1%)
Screen size 5.7 Inch color screen
Waveform display Pressure/flow
IPAP 4~40cm H2O
EPAP 4~25cm H2O
CPAP 4~20cm H2O
Target tidal volume 20~2500mL
Backup BPM 1~60BPM
Backup time 0.2~4.0S
Rise time 1~6 level
Ramp time 0~60min
Ramp pressure CPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief 1~3 level
Spontaneous Timin 0.2~4.0S
Spontaneous Timax 0.2~4.0S
I-Trigger setting Auto, 1~3 level
E-Trigger setting Auto, 1~3 level
Trigger lock Off, 0.3~1.5S
Flow of HFNC mode 10~70L/min
Max flow 300L/min
Max leak compensation 120L/min
Method of pressure measure The pressure testing tube is on mask side
Alarms Apnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted
Apnea alarm range setting 0S, 10S, 20S, 30S
Disconnection alarm range setting 0S, 15S, 60S
Real-time monitoring data Present oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
Other settings Screen lock|Display brightness| Flow| Pressure| Waveform| Event summary
Backup battery 8 hours

 