Mode: | CPAP, Auto CPAP, Bilevel, Auto Bilevel | Pressure Range (cmH2O): | 4-30 |
---|---|---|---|
Pressure Accuracy: | ±0.2 Cm H2O | COMF Pressure Relief: | 1-3 Levels |
Split Night: | YES | Rise Time: | 1-4 Levels |
High Light: | Built in ozone module sleep apnea respirator,Built In Ozone Module bilevel ventilators,CE Bilevel Ventilators |
Micomme Sleep Apnea solution
Description
Home Non-invasive mechanical ventilation (NIV) was originally used in patients with acute respiratory compromises or exacerbations of chronic respiratory diseases as an alternative to intubation.
The ventilator is a machine that uses air pressure to assist the act of breathing performed by the lungs. NIV consists of the ventilator unit itself, some tubing and a mask that you wear to allow the air pressure to enter the respiratory system. NIV is issued when respiratory failure is diagnosed and your medical team believe that you would benefit from your breathing being supported by a ventilator.
Application
Obstructive sleep apnea. Thickened tissues and additional fat stores around the airway, the treatment can reduce the obstruction. a person with sleep apnea rarely gets the rest they need to function at their highest levels throughout the day.
Breathing may become abnormally slow and shallow. Sleep Apnea is a disorder that can be difficult to diagnose properly, it is a condition where there are pauses in breathing or periods of shallow or infrequent breathing during sleep.
Advantage
Professional brand trusted by more than 3000 hospitals. Intelligent preheating, avoid dry and cold.
Built in ozone module, automatic cleaning, prevent infection. 10 abnormal alarms including low tidal volume.
Real time viewing of multiple treatment data.
Water box fully covered by heating base, anti-spilling and easy to clean.
1.72kg, less space, easy to carry.
COMF COMfort Function, it can automatically release the pressure at the key points at the end of exhalation according to the air flow under the mode of autonomous breathing, which makes the pressure conversion of inhalation and exhalation more stable, and greatly improves the comfort and compliance of patients.
Specifications
Model | B5 |
Mode |
CPAP Auto CPAP Bilevel Auto Bilevel |
Pressure range (cmH2O) |
4-30 |
Pressure accuracy | ±0.2 cm H2O |
Max. Operation Pressure | 30 cm H2O |
Ramp time | 0 to 45 min (5-minute increments) |
COMF pressure relief |
1-3 levels |
Humidification | 1-5 levels (113 to 185°F/23 to 85°C |
Rise time | 1-4 levels |
Split night | YES |
Data storage capacity |
8G USB disk |
Weight | 1.72 kg |
Mean sound level | ≤30 dB |