products

70L/M HFNC High Flow Nasal Oxygen Therapy Device

Basic Information
Place of Origin: China
Brand Name: Micomme
Certification: CE
Model Number: OH-70C
Minimum Order Quantity: 10 units
Price: Negotiable
Packaging Details: 78*49*32CM/main unit ; 70*55*23.5CM/trolley
Delivery Time: 10 working days
Payment Terms: L/C, T/T
Supply Ability: 750 units/week
Detail Information
Oxygen Adjustment: Automatic Oxygen Range: 21%- 100%
Low Flow Mode: 2- 25L/min High Flow Mode: 10- 70L/min
Temperature Settings: 31℃-37℃ Screen: 4.3 Inches
Trend Review: 1、3、7 Days Review Dimension: 340*228*162mm
High Light:

HFNC High Flow Nasal Oxygen Therapy Device

,

70L/Min High Flow Nasal Oxygen Therapy Device


Product Description

Micomme medical high flow device with oxygen therapy 70C
 
Description
HFNC is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems.
 
It is considered to have a number of physiological effects: it improves oxygenation, dynamic lung compliance, homogeneity and end expiratory lung volume; it decreases anatomical dead space and generates a positive airway pressure that can reduce respiratory rate, the work of breathing, and enhance patient comfort.
 
Application
When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!
 
HFNC also exerts its effect by providing some variable positive pressure. By providing variable positive pressure, use of high-flow nasal cannula (HFNC) increases functional residual capacity (FRC) by about 25% compared to use of traditional nasal cannula.
 
70L/M HFNC High Flow Nasal Oxygen Therapy Device 0
 
Advantage
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
 
During the pandemic, micomme provided over 7000 units of devices globally.
 
 Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
 
Intelligent water-controlling system, automatically refills and maintains the optimal water level in the water chamber.
 
 Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.
 
70L/M HFNC High Flow Nasal Oxygen Therapy Device 1  70L/M HFNC High Flow Nasal Oxygen Therapy Device 2
 
Specifications
 
 

ModelOH-70C
Oxygen AdjustmentSettingAutomatic
Range21%-100%

 
Flow

Low flow mode2-25L/min
High flow mode10-70L/min
Temperature settings31℃-37℃
Real time monitoring parametersFlow, FiO2, Temperature, Treatment time

 
 
 
Data

Trend review1,3,7 days review
Content of reviewFlow, FiO2, Temperature, Treatment time
Presetting of treatment timeYes

 
 
Management

Auto reminder of maintenanceYes
Main device disinfection

No need disinfection for circuits system
Wipe disinfection for device surface

Screen4.3 inches
Dimension340*228*162mm
Weight3.3kg

 
 
 
Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm

 

Contact Details
Ellen He

Phone Number : +86 19976966601

WhatsApp : +8613808499142